• 12.1″ high-resolution TFT display with LED backlight
• Arrhythmia analysis and S-T segment measurement
• Protection against defibrillator discharge
• Adult/Pediatric/Neonate measurement modes
• Visual and audible alarm; Networking capability
• Up to 9 waveforms simultaneously display
• 140-hour ECG waveform data storage and recall
• 2000-hour data trends with a graphic and tabular view
• 2000 groups event, ARR and SpO2 storage
• Built-in lithium battery; Touch screen optional
ECG | Input dynamic range | ±0.5mVp~±5mVp |
HR measuring range | 15bpm~350bpm | |
HR measuring accuracy | ±1% or ±2bpm, whichever is greater | |
Sensitivity selection | ×1/4, ×1/2, ×1, ×2, ×4 and Auto | |
Sweeping speed | 6.25, 12.5, 25, 50mm/s | |
Common-mode rejection ratio (CMRR) | ≥105dB (Monitoring mode) | |
≥89dB (Diagnostic mode) | ||
NIBP | Technique | Oscillometric |
Typical measurement time | <30 seconds (typical adult cuff) | |
Measuring range | ||
Systolic pressure | Adult: 40mmHg~275mmHg | |
Pediatric: 40mmHg~200mmHg | ||
Neonate: 40mmHg~135mmHg | ||
Diastolic pressure | Adult: 10mmHg~210mmHg | |
Pediatric: 10mmHg~150mmHg | ||
Neonate: 10mmHg~95mmHg | ||
Mean arterial pressure | Adult: 20mmHg~230mmHg | |
Pediatric: 20mmHg~165mmHg | ||
Neonate: 20mmHg~110mmHg | ||
Measurement accuracy | Maximum mean difference: ±5 mmHg | |
Maximum standard deviation: 8 mmHg | ||
Measurement mode | Manual, Auto, STAT | |
Automatic measuring intervals | 1~480min | |
Temperature | Measuring range | 21.0°C~50.0°C |
Measuring accuracy | ±0.2°C for range from 25.0°C~45.0°C | |
Respiration Rate | Measuring range | 0rpm~120rpm |
Measuring accuracy | ±5% or ±2rpm, whichever is greater | |
SpO2 | SpO2 measuring range | 0%~100% |
SpO2 measuring accuracy | 2% for range from 70% to 100% | |
PR measuring range | Low perfusion performance As low as 0.4% | |
PR measuring accuracy | 0bpm~250bpm | |
EtCO2(Optional) | Measuring accuracy | 0mmHg ~ 150mmHg |
Measuring range | ±2bpm or ±2%, whichever is greater | |
Dual IBP(Optional) | Measuring accuracy | -30mmHg ~ 300mmHg |
Measuring range | ±4mmHg or ±2%, whichever is greater | |
Cardiac Output(Opional) | Measuring range | 0.2 ~ 20l/min |
Measuring accuracy | 0.2l/min or 10%, whichever is greater | |
Blood Temperature(BT) | 23°C ~ 45°C | |
Injector Temperature(IT) | 0°C ~ 20°C | |
Cerebral State Monitoring(Optional) | Measuring range | |
Cerebral State Index(CSI) | 0~100 | |
Burst SuppressionRatio(BS%) | 0~100% | |
Forehead EMG Ratio(EMG%) | 0~100% | |
Measuring accuracy | ±2 or ±10%, whichever is greater | |
Others | Power supply | 100~240Vac, 50/60Hz |
Built-in lithium battery | 4400mAh Lithium battery | |
Display | 12.1 inch TFT touch screen | |
Alarming method | Audible-visual alarm | |
Networking port | Ethernet port |
MB 200D is a high frequency electrosurgical equipment suitable for light and medium surgery, allows minimally invasive surgical procedure of resection, evaporation and coagulation.
MB 200D allows pure CUT, Cut-Coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and BIPOLAR coagulation.
Digital reading of delivered power and surveillance through microcontroller of the operational functions, assure absolute reliability of working conditions.
MB 200D allows a highly professional surgery through ergonomic and safety features.
The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode.
Possibility to control the output functions and the delivery of output power by the handle, allows the surgical operation without diverting attention from the surgical field.
– patient-to-plate contact control
– split return electrode use
– minimally invasive surgical treatment allowed
– monopolar and Bipolar indipendent output
– auto Start/Stop in Bipolar Coag
– working condition planning
– power delivery by pedal and/or handle
– digital regulation and indication of the output power
– sound level control
– adjustable power increment
MB 200D is a high frequency electrosurgical equipment suitable for light and medium surgery, allows minimally invasive surgical procedure of resection, evaporation and coagulation.
MB 200D allows pure CUT, Cut-Coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and BIPOLAR coagulation.
Digital reading of delivered power and surveillance through microcontroller of the operational functions, assure absolute reliability of working conditions.
MB 200D allows a highly professional surgery through ergonomic and safety features.
The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode.
Possibility to control the output functions and the delivery of output power by the handle, allows the surgical operation without diverting attention from the surgical field.
– patient-to-plate contact control
– split return electrode use
– minimally invasive surgical treatment allowed
– monopolar and Bipolar indipendent output
– auto Start/Stop in Bipolar Coag
– working condition planning
– power delivery by pedal and/or handle
– digital regulation and indication of the output power
– sound level control
– adjustable power increment
iMEC series
hort Description
The most popular high performance model of Victoria especially suitable for wards, operating rooms, recovery rooms, ICUs, obstetrics and endoscopic applications, etc.
hort Description
The most popular high performance model of Victoria especially suitable for wards, operating rooms, recovery rooms, ICUs, obstetrics and endoscopic applications, etc.