• 12.1″ high-resolution TFT display with LED backlight
• Arrhythmia analysis and S-T segment measurement
• Protection against defibrillator discharge
• Adult/Pediatric/Neonate measurement modes
• Visual and audible alarm; Networking capability
• Up to 9 waveforms simultaneously display
• 140-hour ECG waveform data storage and recall
• 2000-hour data trends with a graphic and tabular view
• 2000 groups event, ARR and SpO2 storage
• Built-in lithium battery; Touch screen optional
| ECG | Input dynamic range | ±0.5mVp~±5mVp |
| HR measuring range | 15bpm~350bpm | |
| HR measuring accuracy | ±1% or ±2bpm, whichever is greater | |
| Sensitivity selection | ×1/4, ×1/2, ×1, ×2, ×4 and Auto | |
| Sweeping speed | 6.25, 12.5, 25, 50mm/s | |
| Common-mode rejection ratio (CMRR) | ≥105dB (Monitoring mode) | |
| ≥89dB (Diagnostic mode) | ||
| NIBP | Technique | Oscillometric |
| Typical measurement time | <30 seconds (typical adult cuff) | |
| Measuring range | ||
| Systolic pressure | Adult: 40mmHg~275mmHg | |
| Pediatric: 40mmHg~200mmHg | ||
| Neonate: 40mmHg~135mmHg | ||
| Diastolic pressure | Adult: 10mmHg~210mmHg | |
| Pediatric: 10mmHg~150mmHg | ||
| Neonate: 10mmHg~95mmHg | ||
| Mean arterial pressure | Adult: 20mmHg~230mmHg | |
| Pediatric: 20mmHg~165mmHg | ||
| Neonate: 20mmHg~110mmHg | ||
| Measurement accuracy | Maximum mean difference: ±5 mmHg | |
| Maximum standard deviation: 8 mmHg | ||
| Measurement mode | Manual, Auto, STAT | |
| Automatic measuring intervals | 1~480min | |
| Temperature | Measuring range | 21.0°C~50.0°C |
| Measuring accuracy | ±0.2°C for range from 25.0°C~45.0°C | |
| Respiration Rate | Measuring range | 0rpm~120rpm |
| Measuring accuracy | ±5% or ±2rpm, whichever is greater | |
| SpO2 | SpO2 measuring range | 0%~100% |
| SpO2 measuring accuracy | 2% for range from 70% to 100% | |
| PR measuring range | Low perfusion performance As low as 0.4% | |
| PR measuring accuracy | 0bpm~250bpm | |
| EtCO2(Optional) | Measuring accuracy | 0mmHg ~ 150mmHg |
| Measuring range | ±2bpm or ±2%, whichever is greater | |
| Dual IBP(Optional) | Measuring accuracy | -30mmHg ~ 300mmHg |
| Measuring range | ±4mmHg or ±2%, whichever is greater | |
| Cardiac Output(Opional) | Measuring range | 0.2 ~ 20l/min |
| Measuring accuracy | 0.2l/min or 10%, whichever is greater | |
| Blood Temperature(BT) | 23°C ~ 45°C | |
| Injector Temperature(IT) | 0°C ~ 20°C | |
| Cerebral State Monitoring(Optional) | Measuring range | |
| Cerebral State Index(CSI) | 0~100 | |
| Burst SuppressionRatio(BS%) | 0~100% | |
| Forehead EMG Ratio(EMG%) | 0~100% | |
| Measuring accuracy | ±2 or ±10%, whichever is greater | |
| Others | Power supply | 100~240Vac, 50/60Hz |
| Built-in lithium battery | 4400mAh Lithium battery | |
| Display | 12.1 inch TFT touch screen | |
| Alarming method | Audible-visual alarm | |
| Networking port | Ethernet port | |
endoscopy,KS0001
endoscopy,KS0001
iMEC series
Short Description
‘-Built on the Reliable Nuvo Platfrom
-Easy access to filter amd hour meter
-Superior Grade of Molecular Sieve
-Spring Mounted High Efficiency compressor
Short Description
‘-Built on the Reliable Nuvo Platfrom
-Easy access to filter amd hour meter
-Superior Grade of Molecular Sieve
-Spring Mounted High Efficiency compressor